1. Designed for use with Enpuda Exceed load frame; can also be used for Criterion load frame with appropriate adapters2. The surface of the fixture is movable and can be customized according to special size requirements3. Improve application performance by manually adjusting the side and adjusting the clamping position in the clamp4. Better test performance and fast operation U-shaped fixture, which can load samples from the side5. Customized large surface6. In each test, the clamping force of the fixture on the sample is the same to minimize operation errors7. The pressure is adjustable, so that the fixture can be used to test various materials8. Keep the clamping force stable to avoid sliding errors and inconsistent measurements9. The anti-corrosion aluminum fixture is lightweight and easy to operate
Code | Description |
ISO 527-3:1995 | Plastics-Determination of tensile properties-Part 3: Test conditions for films and sheets |
ASTM D882-10 | Standard test method for tensile properties of plastic film sheets |
GB/T 1040.3-2006 | Plastics-Determination of tensile properties-Part 3: Test conditions for films and sheets |
model | JDQC203A |
Description | 2 kN pneumatic clamp |
Rated force | 2 kN |
temperature range | Room temperature |
weight | (Upper part) 1.53 kg/(Lower part) 1.53 kg |
Connector style | (Upper part)20 mm/(Lower part)20 mm |
Dimensions (height*width*depth) | (Upper part)150 mm × 170 mm × 77 mm (Lower part)150 mm × 170 mm × 77 mm |
application | Tensile test, tear test |
Application sample | Thin film, thin plate, tear sample |
Compatible framework | E42.503、E43.104、E44.104、E44.304、E45.105、E45.305 |
Push structure | Double acting cylinder |
Contact surface material | rubber |
Fixture opening | 0-10 mm |
Surface width | 30 mm |
Maximum input pressure | 0.8 MPa |