Maximum load: 600kNPurpose: Tensile performance test of various metal and non-metal materials
Code | Description |
ASTM E8M-13 | Standard test method for tensile testing of metallic materials |
ISO 6892-1:2009 | Metallic materials-Tensile test-Part 1: Room temperature test method |
EN 10002-1:200. I | Standard test method for tensile testing of metallic materials |
ASTM A370-10 | Standard test methods for mechanical properties testing of steel products |
ASTM E517-00 | Standard test method for plastic strain ratio r of sheet metal |
ASTM E646-07 | Metallic Materials-Determination of Tensile Strain Hardening Index of Panels and Inserts |
GB/T 228.1-2010 | Metallic materials-Tensile test-Part 1: Room temperature test method |
Description | 50 kN Hydraulic single-sided clamp | 100 kN Hydraulic single-sided clamp | 300 kN Hydraulic single-sided clamp |
Rated force | 50 kN | 100 kN | 300 kN |
temperature range | Room temperature | Room temperature | Room temperature |
Weight (upper part) | 26 kg | 41 kg | 99 kg |
Weight (lower part) | 26 kg | 41 kg | 99 kg |
Connector style (upper) | 40 mm | 40 mm | 60 mm |
Connector style (lower part) | 40 mm | 40 mm | 60 mm |
Dimensions (height*width*depth) (upper part) | 210 mm × 302 mm × 160 mm | 253 mm × 358 mm × 173 mm | 355 mm × 470 mm × 203 mm |
Dimensions (height*width*depth) (lower part) | 210 mm × 302 mm × 160 mm | 253 mm × 358 mm × 173 mm | 355 mm × 470 mm × 203 mm |
application | Tensile test | Tensile test | Tensile test |
Application sample | Metal plastic | Metal plastic | Metal plastic |
Compatible framework | E45.105、E45.305 | E45.105、E45.305 | E45.305 |
Maximum input pressure | 40 MPa | 40 MPa | 40 MPa |