1. Designed for use with Enpuda Exceed load frame; can also be used for Criterion load frame with appropriate adapters
2. In each test, the clamping force of the fixture on the sample is the same to minimize operation errors
3. The pressure is adjustable so that the fixture can be used to test various materials
4. Keep the clamping force stable to avoid sliding errors and inconsistent measurements
5. Provide various holding surfaces to adapt to samples with different shapes, materials and surface textures
6. Clamping force is applied on both sides; the surface moves synchronously to ensure that the sample is accurately placed in the center
7. The U-shaped fixture with better test performance and quick operation can load samples from the side
代码 | 说明 |
ASTM E8M-13 | Standard test method for tensile testing of metallic materials |
ISO 6892-1:2009 | Metallic materials-Tensile test-Part 1: Room temperature test method |
EN 10002-1:2001 | Standard test method for tensile testing of metallic materials |
ASTM A370-10 | Standard test methods for mechanical properties testing of steel products |
ASTM E517-00 | Standard test method for plastic strain ratio r of sheet metal |
ASTM E646-07 | Sheet metal materials-determination of tensile strain hardening index |
GB/T 228.1-2010 | Metallic materials-Tensile test-Part 1: Room temperature test method |
Description | 100 kN hydraulic double-sided clamp |
temperature range | Room temperature |
weight | (Upper part) 60 kg/(Lower part) 60 kg |
Connector style | (Upper part)40 mm/(Lower part)40 mm |
Dimensions (height*width*depth) | (Upper part)245 mm × 380 mm × 221 mm (Lower part)245 mm × 380 mm × 221 mm |
application | Tensile test |
Application sample | Metal plastic |
Compatible framework | E45.105、E45.305 |
Maximum input pressure | 40 MPa |